This is a bilingual snapshot page saved by the user at 2025-1-20 17:44 for https://app.immersivetranslate.com/word/, provided with bilingual support by Immersive Translate. Learn how to save?


Report Number: XGJC-RT/PT-2024-A404-01


InspectionReport


Project Name: Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd. Non-destructive Testing Project


Entrusting Unit: Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd


Beijing Ankero 4.2 tons/hour Food Grade Carbon Dioxide Project FoodWorkpiece Name:


Grade Carbon Dioxide Cold Box


Testing Method:RT,PT (Note: "RT" and "PT" are assumed to be acronyms or proper nouns and thus not translated.) Translation: Testing Method:RT,PT (Note: "RT" and "PT" are kept as they are, assuming they are specific technical terms or acronyms.)


Inspection Date: October 27, 2024 ~ December 17, 2024


Approver:


Approval Date:


Jiangxi Xingguang Testing Technology Co., Ltd


Declaration


1. This report copy is invalid without the consent of our company.


2. This report or any copy thereof without the official seal of the testing institution and the cross-page seal shall be deemed invalid.


3. This report is deemed invalid if it lacks the signatures of the preparer, reviewer, and approver.


4. Tampered reports are invalid.


5. If the photocopied report is not re-stamped with the special report stamp and the cross-page stamp of this testing institution, it is consideredinvalid.


6. This report is only responsible for the inspected parts of the sample.


7、Upon receiving the report, if there are any objections, please raise them within15days.


8. You can verify the authenticity of the report by accessing the Special Equipment Non-destructive Testing Cloud Platform portal (https://ndt.casei.org.cn/) through the "Report Authenticity Inquiry" entrance. You can also verify the authenticity by scanning the QR code on the cover of the report using the mobile app of the cloud platform.


9. If you have any other questions, you can contact us through the following methods.


Jiangxi Xingguang Testing Technology Co., Ltd


Address:Phone:Postal Code:Email:


Jiangxi Province Nanchang City Economic and Technological Development Zone Jingkai Avenue No. 1388 SaiWeilai International City Type B R&D and Production Workshop B11-301 Room

0791-88593595

330013

jxxgndt@126.com


WeChat Mini Program


Mobile APK


Table of Contents


Serial Number


Workpiece Name


Report Number


Page number


Remarks

1


Beijing Ankero 4.2 tons/hour Food Grade Carbon DioxideFood Grade Carbon Dioxide Cold Box Project

XGJC-RT-2024-A404-01

1

/

2


Beijing Ankero 4.2 tons/hour Food Grade Carbon DioxideFood Grade Carbon Dioxide Cold Box Project

XGJC-PT-2024-A404-01

96

/


The following is blank


Ray Detection Report


Report Number: XGJC-RT-2024-A404-01


Project Name


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd. nondestructive testing project


Detection Date


October 27, 2024 ~ December 16, 2024


Inspection Record Number

A404-RT-01`07-01


Entrusting Unit


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd


Workpieceparameters


Workpiece Name


Beijing Anke Luo 4.2 Tons/Hour Food-Grade Carbon Dioxide Project Food-GradeCarbon Dioxide Cold Box


Workpiece Number

A404


Pressure Equipment Category


Pressure pipeline


Detection site


Welded joint


Surface state


Qualified


Technical Requirements


Detection standards

NB/T47013.2-201 5


Detection technology, etc.level


AB Level


Qualified level


Level II


InspectionEquipment


Type of radiation source


X-ray


Instrument Model

XXQ-1005,XXQ-2505


Instrument Number

XG-X-01,XG-X-12


Focus size

0.8mm,2.0mm


Film brand


锐珂 AA400


Film Grade

C5


TechnologicalParameters


Detection Part Code

A404

A404

A404

A404


Specifications (mm)

Φ33×5mm

Φ48×5

Φ60×5

Φ73×7mm


Material

5083

5083

5083

5083


Groove type


V-shaped


V-shaped


V-shaped


V-shaped


Welding method

GTAW

GTAW

GTAW

GTAW


Heat treatment state

/

/

/

/


Timing of detection


Post-welding


Post-welding


Post-welding


Post-welding


Detection ratio

100%

100%

100%

100%


Radiographic Technology


Single Film Radiographic Technique


Single Film Radiographic Technique


Single Film Radiographic Technique


Single Film Radiographic Technique


Transillumination method


Double-Wall Double-Shadow Method


Double-Wall Double-Shadow Method


Double-Wall Double-Shadow Method


Double-Wall Double-Shadow Method


Transillumination parameters F, f, b


700, 663, 37


700, 648, 52

700、636、64


700, 623, 77


Tube voltage

60Kv

70Kv

65Kv

65Kv


Tube current/source strength

5mA

5mA

5mA

5mA


Exposure time (min)

2.0min

0.7min

0.6min

2.0min


Film specifications (mm)

180×80mm

180×80mm

180×80mm

180×80mm


Type and model of image quality meter


Linear/10AlJB


Linear/10AlJB


Linear/10AlJB


Linear/10AlJB


Enhanced screen

2/0.03mm

2/0.03mm

2/0.03mm

2/0.03mm


DarkRoomProcessing


Film processing


Manual flushing


Development conditions


20±2°C/5 minutes (Note: The original text seems to describe a temperature range with a time duration, typically seen in scientific or technical contexts. The translation assumes the context of a temperature setting with a time duration. The "±" symbol indicates a tolerance or variation around the specified value. Here, "20±2℃" means a temperature range from 18°C to 22°C, with a duration of 5 minutes. The translation aims to convey the same technical information in English, maintaining the format and meaning of the original text. If you need further assistance or a different translation, feel free to ask!


Fixing conditions


20±2°C/15min


InspectionDiagram(FabricPattern)


See attachment


Conclusion


A total of 294 joints were inspected, 3 joints were reworked, with 5 sheets reworked, and the first-time pass rate was 98.98%, Grade I sheets 997, Grade II sheets 8, Grade III sheets 0, Grade IV sheets 4.


Note

/


Inspector/Qualification:


RTⅡ


Date:December 18, 2024


Auditor/Qualification:


RTⅡ


Date:December 18, 2024


Testing Agency Seal


Page1of95Page1of97pages


Ray Detection Report


Report Number: XGJC-RT-2024-A404-01


Project Name


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd. nondestructive testing project


Detection Date


October 27, 2024 ~ December 16, 2024


Inspection Record Number

A404-RT-01`07-01


Entrusting Unit


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd


Workpieceparameters


Workpiece Name


Beijing Anke Luo 4.2 Tons/Hour Food-Grade Carbon Dioxide Project Food-GradeCarbon Dioxide Cold Box


Workpiece Number

A404


Pressure Equipment Category


Pressure pipeline


Detection site


Welded joint


Surface state


Qualified


Technical Requirements


Detection standards

NB/T47013.2-201 5


Detection technology, etc.level


AB Level


Qualified level


Level II


InspectionEquipment


Type of radiation source


X-ray


Instrument Model

XXQ-1005,XXQ-2505


Instrument Number

XG-X-01,XG-X-12


Focus size

0.8mm,2.0mm


Film brand


锐珂 AA400


Film Grade

C5


TechnologicalParameters


Detection Part Code

A404

A404

A404

A404


Specifications (mm)

Φ89×5.5

Φ141×7

Φ114×6mm

Φ168×8mm


Material

5083

5083

5083

5083


Groove type


V-shaped


V-shaped


V-shaped


V-shaped


Welding method

GTAW

GTAW

GTAW

GTAW


Heat treatment state

/

/

/

/


Timing of detection


Post-welding


Post-welding


Post-welding


Post-welding


Detection ratio

100%

100%

100%

100%


Radiographic Technology


Single Film Radiographic Technique


Single Film Radiographic Technique

/


Single Film Radiographic Technique


Transillumination method


Double-Wall Double-Shadow Method


Double Wall Single Image Method


Double Wall Single Image Method


Double Wall Single Image Method


Transillumination parameters F, f, b

700、607、93


300, 291, 9


270, 262, 8


320, 310, 10


Tube voltage

60Kv

70Kv

60Kv

60Kv


Tube current/source strength

5mA

5mA

5mA

5mA


Exposure time (min)

2.0min

0.6min

0.3min

0.6min


Film specifications (mm)

180×80mm

180×80mm

180×80mm

180×80mm


Type and model of image quality meter


Linear/10AlJB


Linear/10AlJB


Linear/10AlJB


Linear/10AlJB


Enhanced screen

2/0.03mm

2/0.03mm

2/0.03mm

2/0.03mm


DarkRoomProcessing


Film processing


Manual flushing


Development conditions


20±2°C/5 minutes (Note: The original text seems to describe a temperature range with a time duration, typically seen in scientific or technical contexts. The translation assumes the context of a temperature setting with a time duration. The "±" symbol indicates a tolerance or variation around the specified value. Here, "20±2℃" means a temperature range from 18°C to 22°C, with a duration of 5 minutes. The translation aims to convey the same technical information in English, maintaining the format and meaning of the original text. If you need further assistance or a different translation, feel free to ask!


Fixing conditions


20±2°C/15min


InspectionDiagram(FabricPattern)


See attachment


Conclusion


A total of 294 joints were inspected, 3 joints were reworked, with 5 sheets reworked, and the first-time pass rate was 98.98%, Grade I sheets 997, Grade II sheets 8, Grade III sheets 0, Grade IV sheets 4.


Note

/


Inspector/Qualification:


RTⅡ


Date:December 18, 2024


Auditor/Qualification:


RTⅡ


Date:December 18, 2024


Testing Agency Seal


Page 2of95pagesPage2of97pages


Ray Detection Report


Report Number: XGJC-RT-2024-A404-01


Project Name


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd. nondestructive testing project


Detection Date


October 27, 2024 ~ December 16, 2024


Inspection Record Number

A404-RT-01`07-01


Entrusting Unit


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd


Workpieceparameters


Workpiece Name


Beijing Anke Luo 4.2 Tons/Hour Food-Grade Carbon Dioxide Project Food-GradeCarbon Dioxide Cold Box


Workpiece Number

A404


Pressure Equipment Category


Pressure pipeline


Detection site


Welded joint


Surface state


Qualified


Technical Requirements


Detection standards

NB/T47013.2-201 5


Detection technology, etc.level


AB Level


Qualified level


Level II


InspectionEquipment


Type of radiation source


X-ray


Instrument Model

XXQ-1005,XXQ-2505


Instrument Number

XG-X-01,XG-X-12


Focus size

0.8mm,2.0mm


Film brand


锐珂 AA400


Film Grade

C5


TechnologicalParameters


Detection Part Code

A404

A404

A404

A404


Specifications (mm)

Φ219×8mm

Φ273×12.7mm

Φ88.9×5.49mm

Φ48.3×3.68mm


Material

5083

5083

304

304


Groove type


V-shaped


V-shaped


V-shaped


V-shaped


Welding method

GTAW

GTAW

GTAW

GTAW


Heat treatment state

/

/

/

/


Timing of detection


Post-welding


Post-welding


Post-welding


Post-welding


Detection ratio

100%

100%

100%

100%


Radiographic Technology


Single Film Radiographic Technique


Single Film Radiographic Technique


Single Film Radiographic Technique


Single Film Radiographic Technique


Transillumination method


Double Wall Single Image Method


Double Wall Single Image Method


Double-Wall Double-Shadow Method


Double-Wall Double-Shadow Method


Transillumination parameters F, f, b


370, 360, 10

425、611、14

700、607、93


700, 648, 52


Tube voltage

85Kv

85Kv

120Kv

120Kv


Tube current/source strength

5mA

5mA

5mA

5mA


Exposure time (min)

1.2min

1.8min

3.0min

3.0min


Film specifications (mm)

180×80mm

180×80mm

180×80mm

180×80mm


Type and model of image quality meter


Linear/10AlJB


Linear/10AlJB


Linear/10FeJB


Linear/10FeJB


Enhanced screen

2/0.03mm

2/0.03mm

2/0.03mm

2/0.03mm


DarkRoomProcessing


Film processing


Manual flushing


Development conditions


20±2°C/5 minutes (Note: The original text seems to describe a temperature range with a time duration, typically seen in scientific or technical contexts. The translation assumes the context of a temperature setting with a time duration. The "±" symbol indicates a tolerance or variation around the specified value. Here, "20±2℃" means a temperature range from 18°C to 22°C, with a duration of 5 minutes. The translation aims to convey the same technical information in English, maintaining the format and meaning of the original text. If you need further assistance or a different translation, feel free to ask!


Fixing conditions


20±2°C/15min


InspectionDiagram(FabricPattern)


See attachment


Conclusion


A total of 294 joints were inspected, 3 joints were reworked, with 5 sheets reworked, and the first-time pass rate was 98.98%, Grade I sheets 997, Grade II sheets 8, Grade III sheets 0, Grade IV sheets 4.


Note

/


Inspector/Qualification:


RTⅡ


Date:December 18, 2024


Auditor/Qualification:


RTⅡ


Date:December 18, 2024


Testing Agency Seal


Page 3ofTotal95Pages Page 3 ofTotal97Pages


Ray Detection Report


Report Number: XGJC-RT-2024-A404-01


Project Name


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd. nondestructive testing project


Detection Date


October 27, 2024 ~ December 16, 2024


Inspection Record Number

A404-RT-01`07-01


Entrusting Unit


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd


Workpieceparameters


Workpiece Name


Beijing Anke Luo 4.2 Tons/Hour Food-Grade Carbon Dioxide Project Food-GradeCarbon Dioxide Cold Box


Workpiece Number

A404


Pressure Equipment Category


Pressure pipeline


Detection site


Welded joint


Surface state


Qualified


Technical Requirements


Detection standards

NB/T47013.2-201 5


Detection technology, etc.level


AB Level


Qualified level


Level II


InspectionEquipment


Type of radiation source


X-ray


Instrument Model

XXQ-1005,XXQ-2505


Instrument Number

XG-X-01,XG-X-12


Focus size

0.8mm,2.0mm


Film brand


锐珂 AA400


Film Grade

C5


TechnologicalParameters


Detection Part Code

A404

A404

A404

A404


Specifications (mm)

Φ33.7×3.38mm

Φ60.3×3.91mm

Φ21.3×2.77mm

Φ60.3×3.91mm


Material

304

304

304

304


Groove type


V-shaped


V-shaped


V-shaped


V-shaped


Welding method

GTAW

GTAW

GTAW

GTAW


Heat treatment state

/

/

/

/


Timing of detection


Post-welding


Post-welding


Post-welding


Post-welding


Detection ratio

100%

100%

100%

10%


Radiographic Technology


Single Film Radiographic Technique


Single Film Radiographic Technique


Single Film Radiographic Technique


Single Film Radiographic Technique


Transillumination method


Double-Wall Double-Shadow Method


Double-Wall Double-Shadow Method


Double-Wall Double-Shadow Method


Double-Wall Double-Shadow Method


Transillumination parameters F, f, b


700, 662, 38

700、646、64


700, 675, 25

700、646、64


Tube voltage

120Kv

110Kv

120Kv

110Kv


Tube current/source strength

5mA

5mA

5mA

5mA


Exposure time (min)

3.0min

3.0min

3.0min

3.0min


Film specifications (mm)

180×80mm

180×80mm

180×80mm

180×80mm


Type and model of image quality meter


Linear/10FeJB


Linear/10FeJB


Linear/10FeJB


Linear/10FeJB


Enhanced screen

2/0.03mm

2/0.03mm

2/0.03mm

2/0.03mm


DarkRoomProcessing


Film processing


Manual flushing


Development conditions


20±2°C/5 minutes (Note: The original text seems to describe a temperature range with a time duration, typically seen in scientific or technical contexts. The translation assumes the context of a temperature setting with a time duration. The "±" symbol indicates a tolerance or variation around the specified value. Here, "20±2℃" means a temperature range from 18°C to 22°C, with a duration of 5 minutes. The translation aims to convey the same technical information in English, maintaining the format and meaning of the original text. If you need further assistance or a different translation, feel free to ask!


Fixing conditions


20±2°C/15min


InspectionDiagram(FabricPattern)


See attachment


Conclusion


A total of 294 joints were inspected, 3 joints were reworked, with 5 sheets reworked, and the first-time pass rate was 98.98%, Grade I sheets 997, Grade II sheets 8, Grade III sheets 0, Grade IV sheets 4.


Note

/


Inspector/Qualification:


RTⅡ


Date:December 18, 2024


Auditor/Qualification:


RTⅡ


Date:December 18, 2024


Testing Agency Seal


Page 4of95pagesPage4of97pages


Ray Detection Report


Report Number: XGJC-RT-2024-A404-01


Project Name


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd. nondestructive testing project


Detection Date


October 27, 2024 ~ December 16, 2024


Inspection Record Number

A404-RT-01`07-01


Entrusting Unit


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd


Workpieceparameters


Workpiece Name


Beijing Anke Luo 4.2 Tons/Hour Food-Grade Carbon Dioxide Project Food-GradeCarbon Dioxide Cold Box


Workpiece Number

A404


Pressure Equipment Category


Pressure pipeline


Detection site


Welded joint


Surface state


Qualified


Technical Requirements


Detection standards

NB/T47013.2-201 5


Detection technology, etc.level


AB Level


Qualified level


Level II


InspectionEquipment


Type of radiation source


X-ray


Instrument Model

XXQ-1005,XXQ-2505


Instrument Number

XG-X-01,XG-X-12


Focus size

0.8mm,2.0mm


Film brand


锐珂 AA400


Film Grade

C5


TechnologicalParameters


Detection Part Code

A404

/

/

/


Specifications (mm)

Φ114.3×6.02mm

/

/

/


Material

304

/

/

/


Groove type


V-shaped

/

/

/


Welding method

GTAW

/

/

/


Heat treatment state

/

/

/

/


Timing of detection


Post-welding

/

/

/


Detection ratio

100%

/

/

/


Radiographic Technology


Single Film Radiographic Technique

/

/

/


Transillumination method


Double Wall Single Image Method

/

/

/


Transillumination parameters F, f, b


270, 262, 8

/

/

/


Tube voltage

145Kv

/

/

/


Tube current/source strength

5mA

/

/

/


Exposure time (min)

1.2min

/

/

/


Film specifications (mm)

180×80mm

/

/

/


Type and model of image quality meter


Linear/10FeJB

/

/

/


Enhanced screen

2/0.03mm

/

/

/


DarkRoomProcessing


Film processing


Manual flushing


Development conditions


20±2°C/5 minutes (Note: The original text seems to describe a temperature range with a time duration, typically seen in scientific or technical contexts. The translation assumes the context of a temperature setting with a time duration. The "±" symbol indicates a tolerance or variation around the specified value. Here, "20±2℃" means a temperature range from 18°C to 22°C, with a duration of 5 minutes. The translation aims to convey the same technical information in English, maintaining the format and meaning of the original text. If you need further assistance or a different translation, feel free to ask!


Fixing conditions


20±2°C/15min


InspectionDiagram(FabricPattern)


See attachment


Conclusion


A total of 294 joints were inspected, 3 joints were reworked, with 5 sheets reworked, and the first-time pass rate was 98.98%, Grade I sheets 997, Grade II sheets 8, Grade III sheets 0, Grade IV sheets 4.


Note

/


Inspector/Qualification:


RTⅡ


Date:December 18, 2024


Auditor/Qualification:


RTⅡ


Date:December 18, 2024


Testing Agency Seal


Page 5of95pagesPage 5of97pages


RadiationInspectionReport(ContinuedPage)


Report Number: XGJC-RT-2024-A404-01


Project Name


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd. Non-destructive Testing Project


Workpiece Name


Beijing Ankoro 4.2 tons/hour


Food-grade carbon dioxide project


Food-grade liquid carbon dioxide


box


Detection Part Code

A404-1-BLE60183


Specifications (mm)

Φ33×5


Serial Number


Weld Number


ClipNumber


FilmBlackness


Image Quality MeterSensitivity


DefectNature


Defect Location andDefect Size


QualityGrade


Remarks

1

B5

A

2.0-4.5

13


Not found

/

/

2

B5

B

2.0-4.5

13


Not found

/

/

3

B5

C

2.0-4.5

13


Not found

/

/


The following is blank


Remarks

/


Page 6of95pagesPage6of97pages


RadiationInspectionReport(ContinuedPage)


Report Number: XGJC-RT-2024-A404-01


Project Name


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd. Non-destructive Testing Project


Workpiece Name


Beijing Ankoro 4.2 tons/hour


Food-grade carbon dioxide project


Food-grade liquid carbon dioxide


box


Detection Part Code

A404-1-BLV50229


Specifications (mm)

Φ33×5


Serial Number


Weld Number


ClipNumber


FilmBlackness


Image Quality MeterSensitivity


DefectNature


Defect Location andDefect Size


QualityGrade


Remarks

4

B8

A

2.0-4.5

13


Not found

/

/

5

B8

B

2.0-4.5

13


Not found

/

/

6

B8

C

2.0-4.5

13


Not found

/

/

7

B9

A

2.0-4.5

13


Not found

/

/

8

B9

B

2.0-4.5

13


Not found

/

/

9

B9

C

2.0-4.5

13


Not found

/

/


The following is blank


Remarks

/


Page 7of95pagesPage 7of97pages


RadiationInspectionReport(ContinuedPage)


Report Number: XGJC-RT-2024-A404-01


Project Name


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd. Non-destructive Testing Project


Workpiece Name


Beijing Ankoro 4.2 tons/hour


Food-grade carbon dioxide project


Food-grade liquid carbon dioxide


box


Detection Part Code

A404-1-BLV60125


Specifications (mm)

Φ33×5


Serial Number


Weld Number


ClipNumber


FilmBlackness


Image Quality MeterSensitivity


DefectNature


Defect Location andDefect Size


QualityGrade


Remarks

10

B1

A

2.0-4.5

13


Not found

/

/

11

B1

B

2.0-4.5

13


Not found

/

/

12

B1

C

2.0-4.5

13


Not found

/

/

13

B1-1

A

2.0-4.5

13


Not found

/

/

14

B1-1

B

2.0-4.5

13


Not found

/

/

15

B1-1

C

2.0-4.5

13


Not found

/

/

16

B2

A

2.0-4.5

13


Not found

/

/

17

B2

B

2.0-4.5

13


Not found

/

/

18

B2

C

2.0-4.5

13


Not found

/

/

19

B3

A

2.0-4.5

13


Not found

/

/

20

B3

B

2.0-4.5

13


Not found

/

/

21

B3

C

2.0-4.5

13


Not found

/

/

22

B4

A

2.0-4.5

13


Not found

/

/

23

B4

B

2.0-4.5

13


Not found

/

/

24

B4

C

2.0-4.5

13


Not found

/

/

25

B5

A

2.0-4.5

13


Not found

/

/

26

B5

B

2.0-4.5

13


Not found

/

/


Remarks

/


Page 8of95pagesPage8of97pages


RadiationInspectionReport(ContinuedPage)


Report Number: XGJC-RT-2024-A404-01


Project Name


Jiangxi Pressure Vessel Manufacturing and Installation Co., Ltd. Non-destructive Testing Project


Workpiece Name