Form | Trade of Work Certification | Contractor | Site Supervisory Staff | Submitting Person/Others | Remarks | By-law 25. Certificate of completion and compliance |
G1 | Earthworks | Construction project manager (CIDB) | Site supervisory staff (BEM) | Submitting person (BEM) | BEM: Board of Engineers Malaysia, CIDB: Construction Industry Development Board | |
G2 | Setting Out | Construction project manager (CIDB) |
| Principal submitting person (*BAM/BEM), Licensed land surveyor (LSBM) | BAM: Board of Architects Malaysia, BEM: Board of Engineers Malaysia, CIDB: Construction Industry Development Board, LSBM: Land Surveyors Board Malaysia | |
G3 | Foundation | Construction project manager (CIDB) | ~Site supervisory staff (BEM) | Submitting person (BEM) | BEM: Board of Engineers Malaysia, CIDB: Construction Industry Development Board | |
G4 | Structural | Construction project manager (CIDB) | ~Site supervisory staff (BEM) | Submitting person (BEM) | BEM: Board of Engineers Malaysia, CIDB: Construction Industry Development Board | |
G5 | Internal Water Plumbing | Trade contractor (Licensed plumber) | ~Site supervisory staff (BEM) | Submitting person (*BAM/BEM) | BAM: Board of Architects Malaysia, BEM: Board of Engineers Malaysia | |
G6 | Internal Sanitary Plumbing | Trade contractor (Licensed plumber) | ~Site supervisory staff (BEM) | Submitting person (*BAM/BEM) | BAM: Board of Architects Malaysia, BEM: Board of Engineers Malaysia | |
G7 | Internal Electrical | Trade contractor (Competent person) (EC) | ~Site supervisory staff (BEM) | Submitting person (BEM) | BEM: Board of Engineers Malaysia, EC: Energy Commission | |
G8 | Fire Safety Installation Requirements (Architectural) | Construction project manager (CIDB) | ~Site supervisory staff (BEM) | Principal submitting person (*BAM/BEM) | A certificate of fire safety from the Fire and Rescue Department (except for residential buildings which are not exceeding 18 metres in height) shall be attached with this form. BEM: Board of Engineers Malaysia, CIDB: Construction Industry Development Board | (15) A certificate of fire safety from the Fire and Rescue Department (except for residential buildings of not exceeding 18 metres in height) shall be attached with Forms G8 and G9. |
G9 | Fire Alarm System and Fire Extinguishment System (Mechanical and Electrical) | Trade contractor +( ) | ~Site supervisory staff (BEM) | **Submitting person (BEM) | A certificate of fire safety from the Fire and Rescue Department (except for residential buildings which are not exceeding 18 metres in height) shall be attached with this form. BEM Board of Engineers Malaysia | (15) A certificate of fire safety from the Fire and Rescue Department (except for residential buildings of not exceeding 18 metres in height) shall be attached with Forms G8 and G9. |
G10 | Mechanical Ventilation | Trade contractor +( ) | ~Site supervisory staff (BEM) | Submitting person (BEM) | BEM Board of Engineers Malaysia | |
G11 | Lift/Escalator Installation | Trade contractor (DOSH) | ~Site supervisory staff (BEM) | **Submitting person (BEM) | A certificate of fitness from DOSH shall be attached with this form. BEM: Board of Engineers Malaysia, DOSH: Department of Occupational Safety and Health | (16) A certificate of fitness from the Department of Occupational Safety and Health shall be attached with Form G11. |
G12 | Building | Construction project manager (CIDB) | ~Site supervisory staff (*BAM/BEM) | Principal submitting person (*BAM/BEM) | BAM: Board of Architects Malaysia, BEM: Board of Engineers Malaysia, CIDB: Construction Industry Development Board | |
G13 | External Water Supply System | Trade contractor (SPAN) | ~Site supervisory staff (BEM) | **Submitting person (BEM) | A letter of confirmation from the water authority that the water supply is ready for connection shall be attached with this form. BEM: Board of Engineers Malaysia, SPAN: Suruhanjaya Perkhidmatan Air Negara | (17) A letter of confirmation from the water authority that the water supply is ready for connection shall be attached with Form G13. |
G14 | Sewerage Reticulation | Trade contractor (SPAN) | ~Site supervisory staff (BEM) | **Submitting person (BEM) | A letter of clearance from the sewerage certifying agency shall be attached with this form. BEM: Board of Engineers Malaysia, SPAN: Suruhanjaya Perkhidmatan Air Negara | |
G15 | Sewage Treatment Plant | Trade contractor (SPAN) | ~Site supervisory staff (BEM) | **Submitting person (BEM) | A letter of clearance from the sewerage certifying agency shall be attached with this form. BEM: Board of Engineers Malaysia, SPAN: Suruhanjaya Perkhidmatan Air Negara | (18) A letter of clearance from a sewerage certifying agency shall be attached with Forms G14 and G15. |
G16 | External Electricity Supply System | Trade contractor (Competent person) (EC) | ~Site supervisory staff (BEM) | **Submitting person (BEM) | A letter of confirmation from Tenaga Nasional Berhad that the electrical power supply is ready for connection shall be attached with this form. Not applicable if works are carried out by Tenaga Nasional Berhad BEM: Board of Engineers Malaysia, EC: Energy Commission | (19) A letter of confirmation from Tenaga Nasional Berhad that the electrical power supply is ready for connection shall be attached with Form G16. |
G17 | Road and Drain | Construction project manager (CIDB) | ~Site supervisory staff (BEM) | +Submitting person (BEM) | A letter of confirmation from the *relevant local authority/Public Works Department shall be attached with this form. If the submitting person does not receive the letter of confirmation within fourteen days from the date of application, the letter of confirmation shall be deemed to be given. BEM: Board of Engineers Malaysia, CIDB: Construction Industry Development Board | (20) A letter of confirmation from the relevant local authority or Public Works Department shall be attached with Form G17 and if the letter of confirmation has not been received by the submitting person within fourteen days from the date of application, the letter of confirmation shall be deemed to be given. |
G18 | Street Lighting | Trade contractor (Competent person) (EC) | ~Site supervisory staff (BEM) | Submitting person (BEM) | BEM: Board of Engineers Malaysia, EC: Energy Commission | |
G19 | External Main Drain | Construction project manager (CIDB) | ~Site supervisory staff (BEM) | Submitting person (BEM) | BEM: Board of Engineers Malaysia, CIDB: Construction Industry Development Board | |
G20 | Communication | Trade contractor (EC), ^^Trade contractor (Proficient person) (*MCMC/CA) | ~Site supervisory staff (BEM) | Submitting person (BEM) | For external communication infrastructure works. ^^For internal communication infrastructure and cabling works. BEM: Board of Engineers Malaysia, EC: Energy Commission, MCMC: Malaysian Communications and Multimedia Commission, CA: Certifying Agency | |
G21 | Landscape | Trade contractor +( ) |
| *Architect/Landscape architect +( ) |
|