21-61-00-810-825-A - Pack 2 Compressor Temperature Sensor Fault
TSM 21-61-00-810-825-A - Pack 2 压缩机温度传感器故障

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-00-810-821-A - Pack 2 Electrical Component With Short Circuit (AIR PACK 2 REGUL FAULT)
TSM 21-61-00-810-821-A - Pack 2 电气元件短路(AIR PACK 2 调节故障)

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-11-000-001-A - Removal of the Compressor Outlet-Temperature Sensor
AMM 21-61-11-000-001-A - 拆卸压缩机出口温度传感器

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

FIG. 21-61-83-08 - CONTROL INSTL-PACK TEMPERATURE Zone(s) 190 (Feb 01/24)
IPC-IF 图 21-61-83-08 - 控制 INSTL 包装温度区域 190 (Feb 01/24)

** ON A/C FSN 110-200, 321-350, 361-400, 411-450
** 在空调 FSN 110-200、321-350、361-400、411-450

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-11-400-001-A - Installation of the Compressor Outlet-Temperature Sensor
AMM 21-61-11-400-001-A - 压缩机出口温度传感器的安装

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-00-810-829-A - Pack 2 Compressor Overheat
TSM 21-61-00-810-829-A - Pack 2 压缩机过热

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-00-810-804-A - Pack 2 Fault
TSM 21-61-00-810-804-A - Pack 2 故障

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-00-100-801-A - Cleaning of Temperature Sensor
AMM 21-61-00-100-801-A - 温度传感器的清洁

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-00-810-802-A - Pack 2 Overheat
TSM 21-61-00-810-802-A - Pack 2 过热

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-00-00 CONF 00 - PACK TEMPERATURE CONTROL - DESCRIPTION AND OPERATION - 2. Component Location
AMM 21-61-00-00 CONF 00 - 包装温度控制 - 描述和操作 - 2.组件位置

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-00-00 CONF 00 - PACK TEMPERATURE CONTROL - DESCRIPTION AND OPERATION - 3. System Description - D. Temperature Sensors
AMM 21-61-00-00 CONF 00 - 包装温度控制 - 描述和操作 - 3.系统描述 - D. 温度传感器

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-00-00 CONF 00 - PACK TEMPERATURE CONTROL - DESCRIPTION AND OPERATION - 6. Component Description - G. Compressor Discharge Temperature-Sensor
AMM 21-61-00-00 CONF 00 - 包装温度控制 - 描述和操作 - 6.组件描述 - G. 压缩机排气温度传感器

** ON A/C FSN ALL
** 在 A/C FSN ALL

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

2161-6173 电线 2161-6173

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

2161-6144 - B 电线 2161-6144 - B

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

2161-6144 - R 电线 2161-6144 - R

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

2161-6144 - Y 电线 2161-6144 - Y

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

2161-6172 - R 电线 2161-6172 - R

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

2161-6172 - B 电线 2161-6172 - B

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

2161-6172 - Y 电线 2161-6172 - Y

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

21-61-00-00 CONF 00 - PACK TEMPERATURE CONTROL - DESCRIPTION AND OPERATION - 8. BITE Test - D. CFDS Maintenance Messages
AMM 21-61-00-00 CONF 00 - 包装温度控制 - 描述和操作 - 8.BITE 测试 - D. CFDS 维护消息

** ON A/C FSN 011-016, 018-049, 110-200, 234-235, 239-249, 252-299, 305-315, 321-405, 411-...
** 在 A/C FSN 011-016、018-049、110-200、234-235、239-249、252-299、305-315、321-405、411 上-...

A318, A319, A320, A321 - CES - Revision number: 105 - Revision date: 01-Feb-2024
A318, A319, A320, A321 - CES - 修订号: 105 - 修订日期: 01-Feb-2024

** ON A/C FSN ALL
** 在 A/C FSN ALL
TASK 21-61-00-810-821-A 任务 21-61-00-810-821-A
Pack 2 Electrical Component With Short Circuit (AIR PACK 2 REGUL FAULT)
Pack 2 短路电气元件(AIR PACK 2 调节故障)
1.
Possible Causes: 可能原因:
-P2 FLOW SENSOR (9HB) -P2流量传感器(9HB)
-FLOW CTL UNIT-PACK 2 (24HB)
-SENSOR-DELTA PRESS,PACK 2 (24HB2)
-传感器-DELTA 压力机,PACK 2 (24HB2)
-P2 RAM AIR IN ACTUATOR (28HH)
-执行器中的P2 RAM空气(28HH)
-P2 RAM AIR OUT ACTUATOR (29HH)
-P2 冲压空气输出执行器 (P2 RAM AIR OUT ACTUATOR (29HH)
-P2 CONTROLLER (27HH) -P2控制器(27HH)
-CONT-AIR COND SYSTEM 2 (57HH)
-CONT-AIR COND SYSTEM 2 (57HH) (康特空调系统2 (57HH)
-SENSOR-WATER EXTRACTOR TEMPERATURE (31HH)
-传感器-抽水器温度 (31HH)
-VALVE-TURBINE BYPASS (30HH)
-阀轮旁路 (30HH)
-SENSOR-COMPRESSOR TEMPERATURE (32HH)
-传感器-压缩机温度 (32HH)
-P2 FLOW CTL VALVE (8HB)
-P2流量CTL阀(8HB)
-P2 PRESS INL SENSOR (36HH)
-P2 压入式传感器 (36HH)
-wiring -布线
-SDAC -SDAC公司
2.
Job Set-up Information 作业设置信息
** ON A/C FSN ALL
** 在 A/C FSN ALL
3.
Fault Confirmation 故障确认
** ON A/C FSN ALL
** 在 A/C FSN ALL
SUBTASK 21-61-00-865-057-A
子任务 21-61-00-865-057-A
B.
Open this(these) circuit breaker(s):
打开这个(这些)断路器:
PANEL 面板DESIGNATION 指定FINLOCATION 位置
** ON A/C FSN ALL
** 在 A/C FSN ALL
SUBTASK 21-61-00-865-058-A
子任务 21-61-00-865-058-A
C.
Close this(these) circuit breaker(s):
关闭此(这些)断路器:
PANEL 面板DESIGNATION 指定FINLOCATION 位置
** ON A/C FSN 011-016, 018-049, 110-200, 234-235, 239-249, 252-299, 305-315, 321-405, 411-509, 511-999
** 在 A/C FSN 011-016、018-049、110-200、234-235、239-249、252-299、305-315、321-405、411-509、511-999
SUBTASK 21-61-00-710-090-B
子任务 21-61-00-710-090-B
E.
Test(s) 测试
Ref. Fig. FCV Sensor Plate Inspection Area
参考图。FCV传感器板检测区域
** ON A/C FSN 011-016, 018-049, 110-200, 234-235, 239-249, 252-299, 305-315, 321-405, 411-509, 511-999
- When filtering, no result is given if there is no relationship between MSN/FSN and Figure/Task.
(1)
Read the post flight report.
阅读飞行后报告。
(2)
Read the GROUND REPORT. 阅读地面报告。
(3)
Read the CFDIU CLASS 3 FAULTS Ref. AMM 31-32-00-869-002.
阅读 CFDIU 3 类故障参考 AMM 31-32-00-869-002。
(4)
Do the operational test of the flow control and indicating system Ref. AMM 21-51-00-710-002.
对流量控制和指示系统进行操作测试 参考 AMM 21-51-00-710-002。
(5)
Do the operational test of the pack temperature-control system Ref. AMM 21-61-00-710-001.
对包装温度控制系统进行操作测试,参考编号 AMM 21-61-00-710-001。
** ON A/C FSN ALL
** 在 A/C FSN ALL
4.
Fault Isolation 故障隔离
** ON A/C FSN 011-016, 018-049, 110-200, 234-235, 239-249, 252-299, 305-315, 321-405, 411-509, 511-999
** 在 A/C FSN 011-016、018-049、110-200、234-235、239-249、252-299、305-315、321-405、411-509、511-999
SUBTASK 21-61-00-810-113-B
子任务 21-61-00-810-113-B
A.
Check the below conditions:
检查以下条件:
(1)
If the GROUND REPORT or CFDIU CLASS 3 FAULTS REPORT gives a maintenance message:
如果 GROUND REPORT 或 CFDIU CLASS 3 FAULTS REPORT 给出维护消息:
-
Do the troubleshooting procedure related to the maintenance message.
执行与维护消息相关的故障排除过程。
(2)
If the operational tests confirm the fault:
如果操作测试确认故障:
-
Replace FLOW CTL UNIT-PACK 2 (24HB) Ref. AMM 21-51-51-000-001 and Ref. AMM 21-51-51-400-001.
更换 FLOW CTL UNIT-PACK 2 (24HB) 型号 AMM 21-51-51-000-001 和型号 AMM 21-51-51-400-001。
-
No further action is necessary.
无需采取进一步行动。
(a)
If the post flight report gives the warning AIR PACK 2 REGUL FAULT and the ECAM upper DU shows the warning AIR PACK 2 REGUL FAULT:
如果飞行后报告给出警告 AIR PACK 2 REGUL FAULT,而 ECAM 上部 DU 显示警告 AIR PACK 2 REGUL FAULT:
-
Do the below steps. 执行以下步骤。
NOTE:  注意:
Additional Information  其他信息
For the wiring and the pin identification used in this procedure:
对于此过程中使用的接线和引脚识别:
Ref. ASM 21-51-01,  编号ASM 21-51-01,
Ref. ASM 21-61-01,  编号ASM 21-61-01,
Ref. ASM 21-61-02,  编号 ASM 21-61-02,
Ref. AWM 21-61-06
Search in Aircraft Wiring Manual
Search in GenEWIS (MSN 09205)
,  编号AWM 21-61-06,
Ref. AWM 21-61-07
Search in Aircraft Wiring Manual
Search in GenEWIS (MSN 09205)
,  编号 AWM 21-61-07,
Ref. AWM 21-61-08
Search in Aircraft Wiring Manual
Search in GenEWIS (MSN 09205)
and
参考 AWM 21-61-08 和
Ref. AWM 21-61-09
Search in Aircraft Wiring Manual
Search in GenEWIS (MSN 09205)
. 参考 AWM 21-61-09。
For disconnection/reconnection of the electrical connectors refer to the applicable work step AMM TASK reference in applicable paras. 4. B, C, D and E.
有关电气连接器的断开/重新连接,请参阅适用第 4 段中的适用工作步骤 AMM TASK 参考。B、C、D 和 E。
(3)
If the fault continues: 如果故障仍然存在:
-
Replace SENSOR-DELTA PRESS,PACK 2 (24HB2) Ref. AMM 21-51-11-000-001 and Ref. AMM 21-51-11-400-001 (less probable cause for this failure).
更换 SENSOR-DELTA PRESS,PACK 2 (24HB2) 型号 AMM 21-51-11-000-001 和型号 AMM 21-51-11-400-001(此故障的可能性较小)。
** ON A/C FSN 011-016, 018-049, 110-200, 234-235, 239-249, 252-299, 305-315, 321-405, 411-509, 511-999
** 在 A/C FSN 011-016、018-049、110-200、234-235、239-249、252-299、305-315、321-405、411-509、511-999
SUBTASK 21-61-00-810-187-C
子任务 21-61-00-810-187-C
B.
Check for short circuit at the P2 RAM AIR IN ACTUATOR (28HH) 115VAC supply lines
检查 P2 RAM AIR IN ACTUATOR (28HH) 115VAC 电源线是否短路
(1)
Remove the CONT-AIR COND SYSTEM 2 (57HH),
拆下 CONT-AIR COND SYSTEM 2 (57HH),
Ref. AMM 21-61-34-000-002:
参考 AMM 21-61-34-000-002:
(2)
Disconnect the electrical connector (28HH/A) from the P2 RAM AIR IN ACTUATOR (28HH):
断开电气连接器 (28HH/A) 与 P2 RAM AIR IN ACTUATOR (28HH):
-
do a check for a short circuit between,
检查两者之间的短路,
pins J and K and,
引脚 J 和 K 以及
GND and pins J and K.
GND 和引脚 J 和 K。
-
if there is a short circuit repair the related wiring between,
如果发生短路,请修复之间的相关接线,
connector (28HH/A) pin J and ACSC2 connector (57HH/AB) pin 15J,
连接器 (28HH/A) 引脚 J 和 ACSC2 连接器 (57HH/AB) 引脚 15J,
connector (28HH/A) pin K and ACSC2 connector (57HH/AB) pin 15K.
连接器 (28HH/A) 引脚 K 和 ACSC2 连接器 (57HH/AB) 引脚 15K。
-
if there is no short circuit in the wiring replace the P2 RAM AIR IN ACTUATOR (28HH),
如果接线中没有短路,请更换执行器 (2HH) 中的 P28 RAM 空气,
Ref. AMM 21-61-51-000-001 and,
参考 AMM 21-61-51-000-001 和
Ref. AMM 21-61-51-400-001.
参考 AMM 21-61-51-400-001。
-
install the CONT-AIR COND SYSTEM 2 (57HH)
安装 CONT-AIR COND SYSTEM 2 (57HH)
Ref. AMM 21-61-34-400-002.
参考 AMM 21-61-34-400-002。
-
connect the electrical connector (28HH/A) to the P2 RAM AIR IN ACTUATOR (28HH).
将电气连接器 (28HH/A) 连接到执行器 (28HH) 的 P2 RAM AIR IN。
** ON A/C FSN 011-016, 018-049, 110-200, 234-235, 239-249, 252-299, 305-315, 321-405, 411-509, 511-999
SUBTASK 21-61-00-810-188-B
C.
If the fault continues:
(1)
Swap the ACSC2 (57HH) and the ACSC1 (47HH)
Ref. AMM 21-61-34-000-002 and,
Ref. AMM 21-61-34-400-002.
(a)
If the fault moves with the ACSC2:
-
swap back the ACSC2 (57HH) and the ACSC1 (47HH)
Ref. AMM 21-61-34-000-002 and,
Ref. AMM 21-61-34-400-002.
-
replace the CONT-AIR COND SYSTEM 2 (57HH)
Ref. AMM 21-61-34-000-002 and,
Ref. AMM 21-61-34-400-002.
(2)
If the fault does not move with the ACSC2:
-
swap back the ACSC2 (57HH) and the ACSC1 (47HH)
Ref. AMM 21-61-34-000-002 and,
Ref. AMM 21-61-34-400-002.
** ON A/C FSN 011-016, 018-049, 110-200, 234-235, 239-249, 252-299, 305-315, 321-405, 411-509, 511-999
SUBTASK 21-61-00-810-189-D
D.
If the fault continues:
(1)
Disconnect the electrical connector (31HH/A) from SENSOR-WATER EXTRACTOR TEMPERATURE (31HH):
-
Make sure that all the electrical connections are clean and in the correct condition.
-
Disconnect the electrical connector (28HH/A) from P2 RAM AIR IN ACTUATOR (28HH).
-
At the electrical connector (31HH/A), do a check for the voltage.
(a)
If the voltage is between 9.1VDC and 9.9VDC, connect the electrical connector (31HH/A).
(b)
If the voltage is not between 9.1VDC and 9.9VDC:
1
Connect the electrical connector (28HHA) Ref. AMM 21-61-51-400-001.
2
Do Para. 4.D.(1)(b) again for:
-
The electrical connector (30HH/A) and VALVE-TURBINE BYPASS (30HH) Ref. AMM 21-61-53-000-001 and Ref. AMM 21-61-53-400-001
-
The electrical connector (32HH/A) and SENSOR-COMPRESSOR TEMPERATURE (32HH) Ref. AMM 21-61-11-000-001 and Ref. AMM 21-61-11-400-001
-
The electrical connector (24HB/A) and FLOW CTL UNIT-PACK 2 (24HB) Ref. AMM 21-51-51-000-001 and Ref. AMM 21-51-51-400-001.
** ON A/C FSN 011-016, 018-049, 110-200, 234-235, 239-249, 252-299, 305-315, 321-405, 411-509, 511-999
SUBTASK 21-61-00-810-190-B
E.
If the fault continues:
(1)
Remove CONT-AIR COND SYSTEM 2 (57HH) Ref. AMM 21-61-34-000-002.
(2)
Disconnect the electrical connector (31HH/A) from SENSOR-WATER EXTRACTOR TEMPERATURE (31HH).
(3)
Do a check for a short circuit between pins C and D at the electrical connector (31HH/A).
(4)
Do a check for a short circuit between the GND and pins C and D at the electrical connector (31HH/A).
(a)
If there is no short circuit, connect the electrical connector (31HH/A).
(b)
If there is a short circuit, repair the related wiring between:
-
Electrical connector (31HH/A) pin C and ACSC2 connector (57HH/AA) pin 4A
-
Electrical connector (31HH/A) pin D and ACSC2 connector (57HH/AA) pin 4B.
(c)
Connect the electrical connector (31HH/A).
(5)
If the fault continues:
-
Disconnect the electrical connector (28HH/A) from P2 RAM AIR IN ACTUATOR (28HH).
-
Do a check for a short circuit between pins A and B and A and C at the electrical connector (28HH/A).
-
Do a check for a short circuit between pins B, C and GND and pins A, B and C at the electrical connector (28HH/A).
(a)
If there is no short circuit, connect the electrical connector (28HH/A).
(b)
If there is a short circuit, repair the related wiring between:
-
Electrical connector (28HH/A) pin A and ACSC2 connector (57HH/AA) pin 14B
-
Electrical connector (28HH/A) pin B and ACSC2 connector (57HH/AA) pin 14A
-
Electrical connector (28HH/A) pin C and ACSC2 connector (57HH/AA) pin 14C.
(c)
Connect the electrical connector (28HH/A).
** ON A/C FSN 011-016, 018-049, 110-200, 234-235, 239-249, 252-299, 305-315, 321-405, 411-509, 511-999
SUBTASK 21-61-00-810-194-C
G.
If the fault continues:
(1)
Disconnect the electrical connector (30HH/A) from the VALVE-TURBINE BYPASS (30HH),
-
at the electrical connector (30HH/A) do a check for a short circuit between,
pins U and J, U and K, U and L, J and K, J and L, K and L, C and D and,
GND and pins U, J, K, L and C.
(a)
If there is no short circuit connect the electrical connector (30HH/A).
(b)
If there is a short circuit repair the related wiring between,
connector (30HH/A) pin U and ACSC2 connector (57HH/AB) pin 15D,
connector (30HH/A) pin J and ACSC2 connector (57HH/AB) pin 15A,
connector (30HH/A) pin K and ACSC2 connector (57HH/AB) pin 15B,
connector (30HH/A) pin L and ACSC2 connector (57HH/AB) pin 15C,
connector (30HH/A) pin C and ACSC2 connector (57HH/AB) pin 15E.
-
connect the electrical connector (30HH/A).
** ON A/C FSN 011-016, 018-049, 110-200, 234-235, 239-249, 252-299, 305-315, 321-405, 411-509, 511-999
SUBTASK 21-61-00-810-192-B
H.
If the fault continues:
(1)
Disconnect the electrical connector (32HH/A) from the SENSOR-COMPRESSOR TEMPERATURE (32HH),
-
at the electrical connector (32HH/A) do a check for a short circuit between,
pins B and C, B and D, C and D and,
GND and pins B, C and D.
(a)
If there is no short circuit connect the electrical connector (32HH/A).
(b)
If there is a short circuit repair the related wiring between,
connector (32HH/A) pin B and ACSC2 connector (57HH/AA) pin 6B,
connector (32HH/A) pin C and ACSC2 connector (57HH/AA) pin 6C,
connector (32HH/A) pin D and ACSC2 connector (57HH/AA) pin 6A,
-
connect the electrical connector (32HH/A).
(2)
If the fault continues:
-
disconnect the electrical connector (24HB1/A),
-
at the connector (24HB1/A) do a check for a short circuit between,
pins A and B, A and C, B and C and,
GND and pins A, B and C.
(a)
If there is no short circuit connect the electrical connector (24HB1/A).
(b)
If there is a short circuit repair the related wiring between,
connector (24HB1/A) pin A and ACSC2 connector (57HH/AA) pin 10H,
connector (24HB1/A) pin B and ACSC2 connector (57HH/AA) pin 10K,
connector (24HB1/A) pin C and ACSC2 connector (57HH/AA) pin 10J.
-
connect the electrical connector (24HB1/A).
(3)
Install the CONT-AIR COND SYSTEM 2 (57HH),
Ref. AMM 21-61-34-400-002.
(4)
If the fault continues:
(a)
Swap the SDAC's (1WV2 and 1WV1). (Ref.AMM TASK 31-55-34-401)
(b)
If this action has solved the problem:
-
replace the SDAC which formerly was SDAC2.
** ON A/C FSN ALL
SUBTASK 21-61-00-710-091-A
J.
Do the test as given in the Para. 3.A.
5.
Close-up
SUBTASK 21-61-00-860-070-A
A.
Put the aircraft back to its initial configuration.